        Model  | 
        Standard capacity  | 
        Standard voltage  | 
        Max voltage   | 
        Discharge end voltage  | 
        Standard charge current  | 
        Max charge current  | 
        Max continuous discharge current  | 
        Peak  discharge  
          current  | 
        Cell dimension  | 
        Weight  | 
        Life cycle   | 
        More  
          specification   | 
       
      
        ISR18650 3.7V2500mAh   | 
        2500 mAh  | 
        3.7 V  | 
        4.2 ±0.05 V  | 
        2.75 ±0.05 V  | 
        0.5C  | 
        1C  | 
        2C  | 
        3C  | 
        18x65mm  | 
        <48g  | 
        >600times   | 
         | 
       
      
        ISR18650 3.7V2600mAh   | 
        2600 mAh  | 
        3.7 V  | 
        4.2 ±0.05 V  | 
        2.75 ±0.05 V  | 
        0.5C  | 
        1C  | 
        2C  | 
        3C  | 
        18x65mm  | 
        48g  | 
        >800times   | 
         | 
       
      
        ISR18650 3.6V3000mAh   | 
        3000 mAh  | 
        3.6 V  | 
        4.2 ±0.05 V  | 
        2.75 ±0.05 V  | 
        0.5C  | 
        1C  | 
        2C  | 
        3C  | 
        18x65mm  | 
        48g  | 
        >800times   | 
         | 
       
      | 
  
  
    | With CE,ROHS,MSDS,UN38.3 certificate.  | 
  
  
  
    Cell Electric performance  | 
  
  
    
      
      
      
        ITEM  | 
        CRITERION  | 
        TESTING METHOD  | 
       
      
        Discharge    rate performance  | 
        A)Discharge Performance (0.2C) ≥100%Rated    Capacity  
          B)Discharge    Performance (0.5C) ≥95%Rated Capacity  
          C)Discharge Performance (1C) ≥90%Rated Capacity   
          D)Discharge Performance (2C) ≥80%Rated Capacity   | 
        The cell is charged according to    standard charge method, and then, it is discharged to 2.75V using 0.2C    current; after, the cell is charged according to standard charge method, and    then, it is discharged to 2.75V using 0.5C current; The cell is charged    according to standard charge method, and then, it is discharged to 2.75V    using 1.0C current; At the end, the cell is charged according to standard    charge method, and then, it is discharged to 2.75V using 2.0C current;The    discharge capacities under different current shall be recorded. 
          | 
       
      
        Cycle    life  | 
        ≥600cycle  | 
        Under room temprature, the cell    is charged to 4.2V using 0.5C current and then store it for 10 min. Then it    is discharged to 2.75V using 1C    current. Recycle it continuously till the residual capacity is less than 80%    of the rated capacity.  | 
       
      
        | High-Low temperature discharge performance | 
        Discharge capacity/ initial capactiy×100% A)60℃≥95% rated capacity  
          B)0℃≥80%rated capacity  
          C)-10℃≥70% rated capacity  
          D)-20℃≥55% rated capacity No obvious outside damage, No leakage, No smoke, No explosion | 
        Test the batteries’ initial state and capacity , after standard charging, store it at 60±2℃ for 3 hours, discharge at 0.2C5mA to 2.5V, then make standard charging under room temperature. Then Store it at corresponding constant temperature for 3h under 0±2 ℃/-10±2 ℃/-20±2 ℃ in order. Then discharge the cell at 0.2C5mA to 2.5V and meanwhile make a capacity record. At last store it at room temperature for 2 hours and observe the cell appearance. | 
       
      
        Storage    performance  | 
        Residual Capacity≥90% 
          Rated Capacity   Recovery Capacity≥98% Rated Capacity Internal resistance increase rate≤30%  | 
        After standard fully    charge, make standard discharge. This capacity is    recorded as initial discharge current. Then the    cell is fully charged according to standard charge method and stored at 25℃    for 28 days. After storage, the cell is discharged according to the    requirement of standard discharge method. This discharge capacity is named as the Residual capacity. And then charge and discharge the cell by    0.5C. This discharge    capacity is recorded as the    Recovery capacity.  | 
       
        
        
      | 
  
  
    |   | 
  
  
    Cell Safety characteristics  | 
  
  
    
      
      
      
      
        ITEM  | 
        CRITERION  | 
        TESTING METHOD  | 
       
      
        Overcharge    test  | 
        No flame、No fire、No    explode  | 
        The cell is discharged following    the standard discharge method. Apply a 10V power supply and a 3C charge current for 1.5hrs.  | 
       
      
        130℃ hot oven test  | 
        When the temperature of the cell    is 130℃. Cell must not fire or explode in    30 minutes  | 
        The cell is charged following    the standard charge method. After charging the cell is put in the oven. And    then the oven temperature will be ramped at 5℃ per minute to 130℃ and held at 130℃.  When the temperature    of the cell reach 130℃,    the cell is maintained in the 130℃ oven for a maximum of 30 minutes or until a fire or explosion is obtained.  | 
       
      
        Over    discharge test  | 
        No flame、No fire、No    explode  | 
        Cell shall first be charged    according to standard charge method,and then cell is to be discharged by 0.2C current for 12    hours; The test is completed when the cell is to be discharged up to    250% of rate capacity or the other protective devices prevent the discharge.  | 
       
      
        Crush    test  | 
        No fire、No explode  | 
        After charging a cell following    the standard charge method, the cell shall be crushed between two flat    surfaces. The direction of the crushing force shall be vertical to axis of    the cylinder. The crushing force is to be applied by a hydraulic ram with a 32mm    diameter piston. Crushing force is approximately 13 KN. Once the maximum    pressure has been obtained it is to be released.  | 
       
      | 
  
  
  
       | 
      | 
      | 
      | 
      | 
      | 
  
  
    | Popular models  | 
  
  
     | 
      | 
     | 
      | 
     | 
    Contact us   | 
  
  
     | 
      | 
     | 
      | 
     | 
    SINC BATTERY   | 
  
  
     | 
      | 
     | 
      | 
    Lithium ion cell 18650 3.6V3000mAh | 
    Address: At the 275-km spot to No.102 national road south,Economic-Technological Development Zone,qinhuangdao,China.  | 
  
  
     | 
      | 
     | 
      | 
    Lifepo4 cell 21700 3.2v3000mah  | 
  
  
     | 
      | 
     | 
      | 
    Lithium ion cell 21700 3.6v4000mah  | 
  
  
     | 
      | 
     | 
      | 
     | 
     | 
  
  
     | 
      | 
     | 
      | 
     | 
  
  
     | 
      | 
     | 
      | 
     | 
    Inquire email   | 
  
  
     | 
      | 
     | 
      | 
     | 
     | 
  
  
     | 
      | 
     | 
      | 
     | 
    All inquire will be reply  within 48 hours  | 
  
  
    | Lithium ion battery BMS 24V,36V,48V,60V,72V | 
      | 
     | 
      | 
     | 
      | 
  
  